cooled digital 12bit CCD camera system
- super quantum eff ciency up to 65%
- extremely low noise, down to 4e -rms
- 12bit dynamic range
- thermo-electrical cooling ( Peltier) down to -12 ° C
- high resolution ( 1376 x 1040pixel)
- shutter / exposure times from 500ns -1000s
- binning ( horizontal & vertical)
- region of interest ( ROI)
- 10 frames per second at full CCD resolution
- remote control up to 1500m distance ( with f ber optic link)
- free software camware included
sensicam qe
This high performance cooled digital 12bit CCD camera system comprises advanced CCD and electronics technology. The system features thermo-
electrical cooling of the image sensor ( down to . 12 ° C) , extremely low noise
( down to 4e-rms) and an outstanding quantum eff ciency, which achieves
a high spectral sensitivity in general and especially in the NIR. Exposure
time modes ( software selectable) range from 500ns ( fast shutter) to 1000s
( long exposure) . A high speed serial data link connects the system to the
PC ( f ber optic link available)
| |
unit |
setpoint |
sensicam qe |
| resolution ( hor x ver) [ 1 ] |
pixel |
|
1376 x 1040 |
| pixel size ( hor x ver) |
µm ² |
|
6.45 x 6.45 |
| sensor format / diagonal |
inch / mm |
|
2/ 3″ / 11.14 |
| peak quantum efficiency |
% |
@500nm typical |
62 |
| full well capacity |
e- |
|
18 000 |
| image sensor |
|
|
ICX285AL |
| dynamic range |
dB |
@ gain low, CCD + camera |
70.1 |
| dynamic range A/ D [ 2 ] |
bit |
|
12 |
| readout noise |
e-rms |
@ gain high @ gain low |
4..5 5..6 |
| imaging frequency, frame rate |
fps |
@ full frame @ binning 2x2 |
10.0 19.8 |
| pixel scan rate |
MHz |
|
16 |
| A/D conversion factor |
e- / count |
@ gain high @ gain low |
2 4 |
| spectral range |
nm |
|
290..1100 |
| exposure time |
s |
|
500ns..1000s |
| anti-blooming factor |
|
@ standard light mode @ low light mode @ 100ms exposure time |
> 400 / >4 |
| smear |
% |
|
< 0.002 |
| binning horizontal |
pixel |
|
1,2,4,8 |
| binning vertical |
pixel |
|
1,2,4,8,16,32 |
| region of interest |
pixel |
|
down to 32 x 32 |
| extinction ratio |
|
@ 1ms exposure time |
1 : 2000 |
| non-linearity (differential) |
% |
full temparature range |
< 1 |
| uniformity darkness DSNU[3] |
count |
@ 90% center zone |
1 |
| uniformity brightness PRNU [4] |
% |
|
0.6 |
| trigger, auxiliary signals |
|
internal / external |
software / TTL level |
| power consumption |
W |
|
36 |
| power supply |
VAC |
|
90..260 |
| mechanical dimensions camera ( w x h x l ) |
mm3 |
|
93 x 78 x 210 |
| mechanical dimensions power supply ( w x h x l ) |
mm3 |
|
84 x 50 x 155 |
| weight |
kg |
camera |
1.6 |
| operating temparature range |
oC |
|
+5..+40 |
| operating humidity range |
% |
non condensing |
10..90 |
| storage temparature range |
oC |
|
-20..+70 |
| optical input |
|
|
c-mount with adjustable back focal length |
| optical input window |
|
|
fused silica |
| data interface |
|
|
PCI local bus, Rev. 2.1, burst rate 132 MByte/s |
| CE certified |
|
|
yes |
| cooled CCD temparature |
oC |
|
-12 |
| cooling method |
|
|
2 stage Peltier cooler with forced air cooling |
| modes |
|
light mode / gain mode |
standard - low light standard - high |
- [1] horizontal versus vertical
- [2] Analog-to-Digital-converter
- [3] Dark signal non-uniformity
- [4] Photo response non-uniformity
| data transfer to PC |
standard: twin coaxial cable ( 5m)
optional: f ber optic link ( 10m -1500m)
|
| software |
amware software for camera control, display,
storage and printing of image data under
Windows9x, ME, XP, WindowsNT, Windows2000;
software development kit ( SDK) with demo software
for the above mentioned operating systems; TWAIN
drivers; drivers or plug-ins for popular third party
image processing products
|
| options |
hardened against high magnetic f elds
water cooling
external fan cooling
custom-made versions
|
quantum efficiency
areas of application
- laser induced fluorescence
- fluorescence microscopy
- electron microscopy
- Red and NIR fluorescence applications
- bioluminescence / chemoluminescence
- spectroscopy
- gel imaging
- ion imaging
- low light level imaging
- semiconductor quality control
- imaging of bio markers (e.g. green fluorescent protein, GFP)
Please see the image gallery for some great samples
|
|